Product Description
Intrinsically Safe, Separator ESD System with Annunciation
* ELIMINATES pneumatic freeze ups
* Class1 Div 1, NOT just Div2, Which means the controller can mount INSIDE your Separator Building out of the elements
* Green light good, or Red light bad, on the Annunciation panel, means Easy Operation for fast troubleshooting when the well is down
* GUARANTEED 6 months of battery operation with no sunlight
* built in battery monitor with low power shut down and indicator light
* Up to 1/2 km possible distance for signal wire length
* INTRINSICALLY SAFE, means no cumbersome Teck cable and Explosion Proof connectors or Fittings required ( see picture of silver single pair wire )
** ZERO failure of over 400 units in the field
Intrinsically Safe, Separator ESD System with Annunciation
* ELIMINATES pneumatic freeze ups
* Class1 Div 1, NOT just Div2, Which means the controller can mount INSIDE your Separator Building out of the elements
* Green light good, or Red light bad, on the Annunciation panel, means Easy Operation for fast troubleshooting when the well is down
* GUARANTEED 6 months of battery operation with no sunlight
* built in battery monitor with low power shut down and indicator light
* Up to 1/2 km possible distance for signal wire length
* INTRINSICALLY SAFE, means no cumbersome Teck cable and Explosion Proof connectors or Fittings required ( see picture of silver single pair wire )
** ZERO failure of over 400 units in the field
Product Operation
Normally Closed switches such as a Tank Hi Level , or a separator high pressure etc, are connected to the input channels on the I.S. controller.
In the event that any one of these devices trips, the signal is open, or "lost".
The I.S. Controller will see this signal loss, the status light for that specific alarm will change from green to red.
At this time the I.S. Controller signals the I.S. solenoid, releasing the pneumatic pressure to the ESD valve, and shuts the well in.
** ( ELECTRIC ESD SIGNAL OPTION AVAILABLE WITH INTRINSICALLY SAFE BARRIER / RELAY ) ISSR-2
The status light for the valve changes from green to red.
Once the Alarm has been cleared,( the tank level has been lowered) , simply press the "Reset" button to return the ESD valve to open.
Normally Closed switches such as a Tank Hi Level , or a separator high pressure etc, are connected to the input channels on the I.S. controller.
In the event that any one of these devices trips, the signal is open, or "lost".
The I.S. Controller will see this signal loss, the status light for that specific alarm will change from green to red.
At this time the I.S. Controller signals the I.S. solenoid, releasing the pneumatic pressure to the ESD valve, and shuts the well in.
** ( ELECTRIC ESD SIGNAL OPTION AVAILABLE WITH INTRINSICALLY SAFE BARRIER / RELAY ) ISSR-2
The status light for the valve changes from green to red.
Once the Alarm has been cleared,( the tank level has been lowered) , simply press the "Reset" button to return the ESD valve to open.
OUR PRODUCTS
More Innovative Solar Products
6 v solenoid
|
single pair wire
|
Intrinsically Safe power pack
|
Intrinsically Safe Relay / Barrier
|
6v, 5 w class1 div2 panel
|